Part Number Hot Search : 
PESD2CAN HAT2198 ML4016C S1045 PFZ160 MAC12D 00ETTS TL1431I
Product Description
Full Text Search
 

To Download SPL-45-FE-BZ-CDA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 SFP Bi-Directional Transceiver
SPL-45-FE-BZ
Features * Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10 * Simplex LC Connector * Digital Diagnostic SFF-8472 Compliant * SFP MSA SFF-8074i Compliant * 28.2 dB Minimum Power Budget * 80 km Typical reach * Single 3.3V Supply * 1490nm DFB Laser * Telcordia GR-468 Compliant * RoHS-5/6 Compliant (lead exemption) * Color Coded Bail Latch: Purple
General Operating Condition Parameter Supply Voltage Total Current Power Supply Noise Rejection Operating Temerature(case) (-Cxx) Operating Temerature(case) (-Txx) Storage Temperature Data Rate Topr Topr Tstg DR Symbol Vcc ICC Min. 3.135 100 -5 -40 -40 10 Typ. 3.3 Max. 3.465 300 70 85 85 155 Unit V mA mVp-p C C C Mbps
Transmitter Specifications (Optical) Parameter Optical power Optical crosstalk Average Launch power of off Tx Extinction Ratio Eye Mask Optical Rise time (20% to 80% values) Optical Fall time (20% to 80% values) Mean Wavelength Spectral Width () Relative Intensity Noise Optical Return Loss Tolerance tr tf RIN ORLT 1480 Symbol Pop XT Poff ER Min 0 6.6 Typical +2.5 -45 1490 Max +5 -40 -45 2 2 1500 1 -120 12 Unit dBm dB dBm dB ns ns nm nm dB/Hz dB
IEEE 802.3 and SONET/SDH Compliant
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
1
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-Directional Transceiver
SPL-45-FE-BZ
Transmitter Specifications (Electrical) Parameter Input Differential Impedence PECL Single Ended data input swing TxFault_Fault TxFault_Normal TxDisable_Disable TxDisable_Enable Symbol Rin Vin, p-p Vfault Vnormal Vd Ven Min 80 250 2 Vee 2 Vee Typical 100 Max 120 1200 Vcc Vee + 0.5 Vcc Vee + 0.8 Unit mV V V V V
Receiver Specifications (Optical) Parameter Receiver Power Lowb Receiver Power High Damage Threshold for Receiver Wavelength LOS Assert LOS De-assert LOS hysteresis b) at 10-12 BER, PRBS 27-1 Symbol Rsens,low Rsens,high Pin, damage Min -8 4 1560 -45 0.5 Typical -30 Max -28.2 1580 -28.2 Unit dBm dBm dBm nm dBm dBm dB
Receiver Specifications (Electrical) Parameter PECL Single ended data output swing Data output rise time Data output fall time Symbol Vout,p-p tr tf Min 185 Typical Max 800 2 2 Unit mV ns ns
Timing and Electrical Parameter Tx Disable Negate time Tx Disable assert time Time to initialize, including reset of Tx fault Tx fault Assert time Tx Disable to reset LOS Assert time LOS De-assert time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) LOS output voltage-Fault LOS output voltage-Normal MOD_DEF (0:2)-High MOD_DEF (0:2)-Low Symbol t_on t_off t_init t_fault t_reset t_loss_on t_loss_off f_serial_clock Rx_LOSH RX_LOSL VLOS fault VLOS normal Vh VI Min 10 2 2 Vee 2 Vee Typical Max 25 10 300 100 300 100 100 0.8 Vcc Vee + 0.5 Vcc Vee + 0.5 Unit ms s ms s s s s KHz V V V V V V
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
2
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-Directional Transceiver
SPL-45-FE-BZ
Digital Diagnostics Parameter Temperature (-CDA) Temperature (-TDA) Voltage Bias Current Tx Power Rx Power Range -5 to 70 -40 to 85 0 to Vcc 0 to 120 0 to +5 -28.2 to -8 Accuracy 3 3 0.1 5 3 3 Unit C C V mA dBm dBm Calibration Internal Internal Internal External External External Bit Value 1/256 C 1/256 C 100V Formula Tc(C) = Tad(16 bit signed twos complement)/256 Tc(C) = Tad(16 bit signed twos complement)/256 V(Volts) = Vad(16 bit unsigned integer)*0.1 I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx_PWR(W) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx_PWR(W) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function VeeT TX_FAULT TX_DISABLE MOD_DEF2 MOD_DEF1 MOD_DEF0 NC LOS VeeR VeeR VeeR RXDRXD+ VeeR VCCR VCCT VeeT TXD+ TXDVeeT Notes TX GND Open Collector Internally Pulled High Serial Data Input Serial Clock Input Internally Grounded Not Connected Open Collector RX Ground RX Ground RX Ground RX Data Negative RX Data Positive RX GND RX Power TX Power TX GND TX Data Positive TX Data Negative TX GND
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
3
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-Directional Transceiver
SPL-45-FE-BZ
EEPROM Serial ID Name of Field Discription of Field Address 20 21 22 23 24 Vendor Name SFP Vendor name (ASCII) 25 26 27 28 29 30 37 Vendor OUI IEEE vendor OUI code for LuminentOIC 38 39 40 41 42 43 44 Vendor P/N Part number in ASCII, e.g. SPL-45-GB-BZ-CDA 45 46 47 48 49 50 51 Hex 4C 55 4D 49 4E 45 4E 54 4F 49 43 00 06 B5 53 50 4C 34 35 46 45 42 5A 43 44 41 S P L 4 5 F E B Z C D A ASCII L U M I N E N T O I C
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
4
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-Directional Transceiver
SPL-45-FE-BZ
LC Connector Mechanical
Units in mm (inches)
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
5
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-Directional Transceiver
SPL-45-FE-BZ
Suggested Transceiver Interface
1H
Vcc
10F 0.1F 1H
.01F VCCT
Protocol IC
R1
TX_DISABLE
10K TX_DISABLE
LuminentOIC SFP
TX_FAULT
TX_FAULT
Laser Driver
.01F
SerDes
TD +
100 TD VEET .01F
VCCR
10F 0.1F
RD +
Receiver Amplifier
.01F
100
RD -
RX_LOS
Vcc
RX_LOS
R
1
.01F
VEER
EEPROM
R1
R1
R1
MOD_DEF 2 MOD_DEF 1
R1=4.7K to 10K
MOD_DEF 0
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
6
LUMNDS1566-Nov0606 Rev A.1
SFP Bi-directional Transceiver
SPL-45-FE-BZ
Ordering Information Available Options: SPL-45-FE-BZ-CDA SPL-45-FE-BZ-CNA SPL-45-FE-BZ-TDA SPL-45-FE-BZ-TNA Part numbering Definition:
S P L - 4 5 - F E - B Z - Temperarure
* SPL = LC connector * Wavelength 45 = Tx 1490nm/Rx 1570nm * Data Rate FE = Fast Ethernet (100Mbps) * Standard BZ = 80km reach * Operating Temperarure C= Commercial temperature (-5 to 70C) T= Industrial temperature (-40 to 85C) * D = Digital Diagnostic N = No Digital Diagnostic * Revision A=RoHS 5/6-compliant product (lead exemption) Warnings:
Diagnostic
Revision
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC's sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company's standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company's Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
7
LUMNDS1566-Nov0606 Rev A.1


▲Up To Search▲   

 
Price & Availability of SPL-45-FE-BZ-CDA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X